Description
Description
With its compact design, the 1600 insert can be installed in a fireplace as small as 14 3/8'' deep. Even so, it offers a performance of up to 65,000 BTU/hr and burns 17'' logs.
The standard 130-CFM blower helps maximize the stove's energy performance and the very low emission rate, even at normal operating temperatures, makes the 1600 insert an excellent choice for those seeking an environmentally friendly but ultra-efficient source of heat.
Required Accessories:
Requires the addition of one each of (A), (B) and (C) required accessories to complete the unit
A:
- OA10230 Black Cast Iron Door Overlay
- OA10231 Brown Cast Iron Door Overlay
- OA10232 Gold Plated Cast Iron Door Overlay
- OA10234 Brushed Nickel Cast Iron Door Overlay
B:
- OA10300 Regular Faceplate - 29" X 44"
C:
- OA10121 Brass Faceplate Trim Kit - 29" X 44"
- OA10122 Black Faceplate Trim Kit - 29" X 44"
- OA10123 Brushed Nickel Faceplate Trim Kit - 29" X 44"
- OA10124 Brass Faceplate Trim Kit - 32" X 44"
- OA10125 Black Faceplate Trim Kit - 32" X 44"
- OA10126 Brushed Nickel Faceplate Trim Kit - 32" X 44"
Features
Features
Fuel type: | Dry cordwood |
Recommended heating area (sq.ft.): | 500 - 1,800 |
Firebox volume (cu. ft.): | 2.0 |
Maximum burn time: | 6 h |
Maximum heat output (dry cordwood): | 65,000 BTU/h (19.0 kW) |
Overall heat output rate (min. to max.): | 11,800 BTU/h (3.5 kW) to 42,400 BTU/h (12.4 kW) |
Average overall efficiency (EPA cribs / Douglas fir): |
68.0 % (HHV) 73.0 % (LHV) |
Average overall efficiency (dry cordwood): |
N.A. (HHV) N.A. (LHV) |
Optimum efficiency: | 80 % |
Average particulate emissions rate: | 4.44 g/h |
Average CO: | N.A. |
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(Average overall efficiency) As measured per CSA B415.1-10 stack loss method.
(HHV) Higher Heating Value of the fuel.
(LHV) Lower Heating Value of the fuel.
(Optimum efficiency) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
This appliance is officially tested and certified by an independent agency.
Specifications
Specifications
Maximum log length: | 17'' |
Log positioning: | Over width |
Chimney diameter: | 6" |
Minimum chimney height (feet): | 12' |
Baffle type: | C-Cast |
Approved for a mobile home installation: | No |
Shipping Weight: | 378 lb (172 kg) |
Door type: | Single, glass with cast iron frame |
Glass type: | Ceramic glass |
Glass surface – dimensions (Width X Height): | 15'' x 8 3/8'' |
Glass air-wash system: | Yes |
Premium quality blower included (CFM): | 130 |
Overall dimension (Height): | 22 5/8'' |
Overall dimension (Width): | 25 7/8'' |
Overall dimension (Depth): | 26'' |
Door opening – dimension (Height): | 8 1/2'' |
Door opening - dimension (Width): | 15 5/8'' |
Firebox – dimension (Height) | 12 7/8'' |
Firebox – dimension (Width) | 18 1/8'' |
Firebox – dimension (Depth): | 14 3/4'' |
Firebox lined with refractory bricks for better heat distribution: | Yes |
Stainless-steel secondary-air system improving gas combustion: | Yes |
Adjustable threaded legs: | Yes |
Steel thickness – body: | 3/16" |
Steel thickness – top: | 5/16" |
Centre line of flue outlet to the side: | 12 1/8'' |
Centre line of flue outlet to the back: | 6'' |
Fireplace opening – minimum (Height): | 22 5/8 |
Fireplace opening – minimum (Width): | 26 3/8" |
Fireplace opening – minimum (Depth): | 14 3/8" |
USA standard (emissions): | EPA |
Canadian Standard (emissions): | CSA B415.1-10 |
USA standard (safety): | UL 1482, UL 907 |
Canadian standard (safety): | ULC S628 |
Tested and listed as per applicable standards: | By an accredited laboratory (CAN/USA) |
Warranty: | Limited lifetime |
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
Canada | USA | |
Clearance – top (measured from the platform on which the appliance is installed)** | N.A. | N.A. |
Clearance – minimum floor protection in front of the appliance | 18" | 16" |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites). | ||
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual. |