Description
Description
The 2300 model, one of our new-generation wood stoves, comes from the drawing board to you, backed by the advanced technology of Solid-Edge, a 3-D software design program. It features an aesthetically pleasing cast-iron door complete with the Osburn logo, hidden latch and hinges, and extra-large glass window.
Each appliance is equipped with a premium quality blower. The secondary air tubes and baffle ensure combustion of the highest quality.
Read on to find out more about the sophisticated qualities and distinctive look of the 2300.
Required Accessories:
Requires the addition of one each of (A) and (B) required accessories to complete the unit
A:
- OA10069 Brown Cast Iron Door Overlay
- OA10073 Black Cast Iron Door Overlay
- OA10074 Gold Cast Iron Door Overlay
- OA10075 Brushed Nickel Cast Iron Door Overlay
B:
- OA10076 Black Leg Kit With Ash Pan
- OA10077 Gold Plated Leg Kit With Ash Pan
- OA10078 Brushed Nickel Leg Kit With Ash Pan
- OA10079 Pedestal With Ash Pan
Features
Features
Fuel type: | Dry cordwood |
Recommended heating area (sq.ft.): | 900 - 2,300 |
Firebox volume (cu. ft.): | 3.4 |
Maximum burn time: | 10 h |
Maximum heat output (dry cordwood): | 90,000 BTU/h (26.4 kW) |
Overall heat output rate (min. to max.): | 11,700 BTU/h (3.4 kW) to 26,400 BTU/h (7.7 kW) |
Average overall efficiency (EPA cribs / Douglas fir): |
67.5 % (HHV) 72.9 % (LHV) |
Average overall efficiency (dry cordwood): |
N.A. (HHV) N.A. (LHV) |
Optimum efficiency: | 75 % |
Average particulate emissions rate: | 4.5 g/h |
Average CO: | 165.6 g/h |
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(Average Overall Efficieny) As measured per CSA B415.1-10 stack loss method.
(HHV) Higher Heating Value of the fuel.
(LHV) Lower Heating Value of the fuel.
Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
Optimum overall efficiency at a specific burn rate (LHV).
This appliance is officially tested and certified by an independent agency.
Specifications
Specifications
Maximum log length: | 20" |
Log positioning: | Over depth |
Chimney diameter: | 6" |
Flue outlet diameter: | 6" |
Minimum chimney height (feet): | 12' |
Baffle type: | C-Cast |
Approved for a mobile home installation: | Yes |
Shipping Weight: | 450 lb (204 kg) |
Door type: | Single, glass with cast iron frame |
Glass type: | Ceramic glass |
Glass surface – dimensions (Width X Height): | 15 1/8'' X 10 7/8'' |
Glass air-wash system: | Yes |
Premium quality blower included (CFM): | 100 |
Overall dimension (Height): | 33 5/8" |
Overall dimension (Width): | 25 3/4" |
Overall dimension (Depth): | 34 7/8'' |
Door opening – dimension (Height): | 11 1/2'' |
Door opening - dimension (Width): | 15 1/2'' |
Firebox – dimension (Height): | 14 7/8'' |
Firebox – dimension (Width): | 18 3/8" |
Firebox – dimension (Depth): | 21 1/4'' |
Firebox lined with refractory bricks for better heat distribution: | Yes |
Stainless-steel secondary-air system improving gas combustion: | Yes |
Model: | Legs or pedestal |
Adjustable threaded legs: | Yes |
Steel thickness – body: | 3/16" |
Steel thickness – top: | 5/16" |
Centre line of flue outlet to the side: | 12 1/8" |
Centre line of flue outlet to the back: | 6 3/4" |
Easy-to-access ash drawer: | Yes |
USA standard (emissions): | EPA Method 28 |
Canadian Standard (emissions): | CSA B415.1-10 |
USA standard (safety): | UL 1482 |
Canadian standard (safety): | ULC S627 |
Tested and listed as per applicable standards: | By an accredited laboratory (CAN/USA) |
Warranty: | Limited lifetime |
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
Canada USA
Single wall pipe | Double wall pipe | Single wall pipe | Double wall pipe | |
Clearance – back wall | 15" | 6" | 12" | 6" |
Clearance – side wall | 12" | 12" | 12" | 12" |
Clearance – placed in a corner | 10" | 10" | 10" | 10" |
Clearance – top (measured from the platform on which the appliance is installed)** | 84" | 84" | 84" | 84" |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.