Rinnai Water Heater Extension Vent Pipe 19.5"

224052

Models: RL75i, RL94i, RE180i, RE199i, RU199i

Status: Arriving Soon

US$86.99

Description

Description

The Rinnai Water Heater Extension Vent Pipe 19.5", part number 224052, is a vent pipe extension section designed to increase the length of a Rinnai concentric vent system on compatible non-condensing tankless water heaters. It provides additional pipe length to help reach appropriate termination locations while maintaining the proper dual-flow (exhaust and intake) design of the system. This extension is engineered to match the original vent components, ensuring correct fit, sealing, and airflow characteristics when installed as part of a certified vent system.

This extension vent pipe is intended for indoor installations where a Rinnai concentric vent run must be lengthened to meet building configuration or clearance requirements. It features an inner exhaust tube and outer intake sleeve, maintaining the concentric design that supports simultaneous exhaust and combustion air intake. Installation must follow the manufacturer’s certified venting instructions to ensure proper clearances to combustibles and secure connections throughout the vent run.

What’s Included: One (1) Rinnai 19.5" extension vent pipe section.

Installation Limits: For use with compatible Rinnai non-condensing water heaters that utilize a concentric vent system; install as part of a listed venting assembly and maintain required clearances and secure connections per the venting instructions.

Compatibility: Compatible with indoor Rinnai non-condensing tankless water heaters equipped with a concentric vent system that accepts a 19.5" extension section.

Features

Features

  • Vent pipe extension section for Rinnai concentric vent systems
  • Part number 224052 for accurate identification
  • Provides 19.5" of additional vent pipe length
  • Maintains dual-flow concentric design for exhaust and intake
  • Designed for non-condensing indoor tankless water heater venting
  • Matches fit and connection characteristics of original vent components
  • Supports meeting termination and clearance requirements in installations

Specifications

Specifications

Product Type: Vent Pipe Extension
Brand: Rinnai
Manufacturer Part Number: 224052
Application: Extending concentric venting on Rinnai non-condensing tankless water heaters
Function: Provides additional vent length while preserving intake/exhaust pathways
Compatible Models: Indoor Rinnai non-condensing tankless water heaters with concentric vent systems

 

Install this extension as part of the certified venting system following the manufacturer’s venting instructions to ensure safe clearance, secure connections, and intended airflow performance.

 

Support

Support

 
Product FAQ

Q. What is the purpose of the Rinnai 224052 vent pipe extension?

A. It adds 19.5 inches of length to a Rinnai concentric vent system to help meet required vent termination distances and installation layouts.

Q. Can this extension be shortened during installation?

A. It may be trimmed in accordance with manufacturer venting instructions to accommodate specific installation requirements.

Q. Is this compatible with all Rinnai tankless water heaters?

A. It is compatible with indoor non-condensing Rinnai tankless water heaters that use a certified concentric vent system; models using separate intake and exhaust venting require different components.

Q. What type of vent system does this extension support?

A. It supports Rinnai concentric vent systems where exhaust exits through the inner pipe and combustion air is drawn through the outer passage.

Q. Does this extension affect clearance requirements?

A. Clearance requirements remain governed by the certified venting system and must be maintained according to the manufacturer’s installation instructions.

Q. Should professional installation be considered?

A. Professional installation is recommended to ensure correct assembly, secure connections, and compliance with venting and safety requirements.

To top