The DuraVent DirectVent Pro 24-Inch Pipe Length, part number 58DVA-24, is the galvanized 24-inch fixed-length rigid pipe section for the DirectVent Pro 5-inch by 8-inch coaxial direct vent system for gas and propane appliances. The 58DVA-24 is a standard fixed-length rigid pipe section providing a nominal 24-inch — two-foot — length increment in a DirectVent Pro vent run.
It occupies the mid-range position in the DirectVent Pro 5x8 fixed-length pipe range, providing twice the nominal length of the 58DVA-12 12-inch section per connection joint and serving as a practical building block for vent runs of moderate length where the longer 36-inch, 48-inch, and 60-inch sections would overshoot the required total and the 12-inch section would require an excessive number of joints to build the same run.
Like all DirectVent Pro rigid pipe lengths, the 58DVA-24 is a fully unitized coaxial section — the inner pipe exhausts flue gases from the appliance to the outside while the outer pipe simultaneously draws combustion air from outside into the appliance through the annular space between the two pipes.
The inner wall is .020-inch aluminum and the outer wall is .018-inch galvanized steel. No gaskets or sealants are required at connections unless specifically required by the appliance manufacturer's installation instructions. Fully unitized twist-lock construction connects inner and outer walls as a single unit with no beads or hems. The 58DVA-24 is available in black painted outer finish as the 58DVA-24B for visible interior vent sections. A separate adjustable pipe section — the 58DVA-24TA — provides an adjustable range of 17 to 24 inches and is a distinct product from the fixed-length 58DVA-24.
To calculate the installed length contribution of the 58DVA-24, subtract 1-1/2 inches per joint — the 24-inch nominal section contributes approximately 22-1/2 inches of installed length per section. Always confirm the vent system and configuration against the appliance manufacturer's installation instructions before installation.
What's Included: One DuraVent 58DVA-24 DirectVent Pro 5-inch by 8-inch galvanized 24-inch fixed-length rigid pipe section.
Installation Limits: Fixed 24-inch nominal length — subtract 1-1/2 inches per joint for installed length calculation, giving approximately 22-1/2 inches installed length per section. No gaskets or sealants required unless specified by the appliance manufacturer. Confirm vent system approval against the specific appliance manufacturer's installation instructions before installation. All installation must comply with local building codes.
Compatibility: Compatible with the DuraVent DirectVent Pro 5-inch by 8-inch coaxial direct vent system for direct vent gas and propane stoves, heaters, and fireplaces. Not compatible with DirectVent GS pipe.