Eskabe Vent-Air Intake Pipe, DVEL8

5089

Status: In Stock

US$8.99

Description

Description

The Eskabe Vent-Air Intake Pipe, part number 5089, is the combustion air intake pipe replacement part for the Eskabe DVEL8 gravity direct vent wall furnace vent kit. The DVEL8 is a non-electric, 8,000 BTU/h direct vent wall furnace available in natural gas and propane configurations, designed to vent horizontally through any exterior wall up to 10 inches thick.

The DVEL8 vent system is a coaxial — dual-wall — design: the inner vent pipe exhausts hot flue gases from the appliance to the outside, while the outer air intake pipe — the 5089 — draws cooler combustion air from outside through the annular space between the outer and inner pipes into the appliance for combustion. This sealed combustion design uses no interior room air, ensuring clean indoor air quality and efficient operation.

The 5089 Vent-Air Intake Pipe is the outer pipe component of the DVEL8 coaxial vent assembly, functioning as the combustion air inlet that surrounds and protects the inner exhaust pipe as the vent assembly passes through the exterior wall. No special insulation or fireproofing of the wall opening is required for the DVEL8 vent kit.

The vent assembly accommodates walls up to 10 inches thick. The companion inner exhaust pipe for the DVEL8 is the Eskabe 5134 Vent Pipe, which carries the hot combustion gases from the appliance through the center of the vent assembly to the exterior. Both the 5089 and 5134 are genuine Eskabe OEM replacement parts for maintaining the DVEL8 vent system in service.

Installation and service of the DVEL8 and its vent components must be performed by a qualified installer, service agency, or the gas supplier in accordance with local codes.

What's Included: One Eskabe 5089 Vent-Air Intake Pipe replacement part for the DVEL8 gravity direct vent wall furnace.

Installation Limits: For use with the Eskabe DVEL8 gravity direct vent wall furnace only. The companion inner exhaust pipe is the Eskabe 5134 Vent Pipe, sold separately. Wall penetration accommodates walls up to 10 inches thick. Installation and service must be performed by a qualified installer, service agency, or the gas supplier in accordance with local codes. Use only the type of gas indicated on the DVEL8 rating plate.

Compatibility: Genuine Eskabe OEM replacement part for the DVEL8 gravity direct vent wall furnace vent kit — natural gas (DVEL8N) and propane (DVEL8L) models.

Features

Features

  • Genuine Eskabe OEM replacement vent-air intake pipe for the DVEL8 gravity direct vent wall furnace — the outer pipe of the DVEL8 coaxial vent assembly that draws combustion air from outside into the appliance
  • The DVEL8 coaxial vent design uses no interior room air for combustion — the outer air intake pipe surrounds the inner exhaust pipe as the vent passes through the wall, with outside air flowing inward through the annular space
  • Compatible with DVEL8 vent installations through exterior walls up to 10 inches thick — no special insulation or fireproofing of the wall opening required
  • Companion inner exhaust pipe for the DVEL8 is the Eskabe 5134 Vent Pipe — the 5089 and 5134 together complete the DVEL8 coaxial vent assembly
  • For use with the Eskabe DVEL8 8,000 BTU/h non-electric gravity direct vent wall furnace — available in natural gas (DVEL8N) and propane (DVEL8L) configurations
  • Installation and service must be performed by a qualified installer, service agency, or the gas supplier in accordance with all applicable local codes

Specifications

Specifications

Part Number: 5089
Brand: Eskabe
Part Type: Vent-Air Intake Pipe — Outer Coaxial Combustion Air Pipe
Compatible Appliance: Eskabe DVEL8 Gravity Direct Vent Wall Furnace
Compatible Models: DVEL8N (Natural Gas) and DVEL8L (Propane)
Appliance Input: 8,000 BTU/h
Vent System Type: Coaxial Direct Vent — Dual-Wall
Wall Thickness Accommodation: Up to 10 Inches
Companion Part: Eskabe 5134 Vent Pipe — Inner Exhaust Pipe — Sold Separately
Part Status: Genuine Eskabe OEM Replacement Part

 

The Eskabe 5089 is the genuine OEM replacement vent-air intake pipe — the outer combustion air pipe of the DVEL8 coaxial direct vent assembly — for the Eskabe DVEL8 8,000 BTU/h non-electric gravity direct vent wall furnace, compatible with walls up to 10 inches thick and both natural gas and propane DVEL8 models, with companion inner exhaust pipe Eskabe 5134 sold separately.

 

Support

Support

 
Product FAQ

What is the role of the 5089 Vent-Air Intake Pipe in the DVEL8 vent system?

The 5089 Vent-Air Intake Pipe is the outer pipe of the DVEL8 coaxial — dual-wall — vent assembly. In the DVEL8's direct vent system, the inner pipe carries hot exhaust gases from the appliance outward through the wall to the exterior, while the outer 5089 air intake pipe surrounds the inner exhaust pipe and draws cooler outside combustion air inward through the annular space between the two pipes to supply the appliance burner. This coaxial arrangement means both exhaust and combustion air share a single wall penetration, with the two gas streams flowing in opposite directions through the inner and outer pipes simultaneously. The 5089 is the outer structural pipe that contains both the exhaust and the intake flows as the vent assembly passes through the wall, and also protects the inner exhaust pipe from the wall cavity environment.

What is the difference between the Eskabe 5089 and the Eskabe 5134?

The 5089 and 5134 are the two pipe components of the DVEL8 coaxial vent assembly — they are different parts serving opposite functions. The 5089 is the outer air intake pipe that draws combustion air from outside into the appliance through the annular space between the outer and inner pipes. The 5134 is the inner vent pipe that carries hot exhaust gases from the appliance burner outward through the center of the assembly to the exterior. Together they form the complete DVEL8 vent assembly. When servicing or replacing vent components, the specific pipe that has failed must be identified — the outer air intake 5089 or the inner exhaust 5134 — and the correct replacement part ordered accordingly. Both parts are genuine Eskabe OEM replacement parts available from Rural Energy.

Why does the DVEL8 direct vent system require no special insulation or fireproofing at the wall opening?

The DVEL8 direct vent system does not require special insulation or fireproofing at the wall opening because the coaxial design keeps the outer pipe surface cool during operation. The combustion air flowing inward through the annular space between the outer and inner pipes absorbs heat from the inner exhaust pipe, cooling the inner pipe while simultaneously preheating the incoming combustion air. This heat exchange effect keeps the outer pipe surface — which contacts the wall opening — at a temperature that does not require the additional clearance or fire separation materials needed for higher-temperature venting systems. This is one of the practical installation advantages of the DVEL8's direct vent coaxial design compared to conventional single-pipe venting systems.

Is the 5089 compatible with both the natural gas and propane versions of the DVEL8?

Yes. The 5089 Vent-Air Intake Pipe is a vent system component that is mechanically the same for both the natural gas DVEL8N and the propane DVEL8L versions of the DVEL8 wall furnace. The vent assembly's function — drawing combustion air inward and exhausting flue gases outward through the wall — is the same regardless of fuel type. The differences between the natural gas and propane DVEL8 models are in the gas valve, orifice, and pressure regulator settings — the vent assembly components are shared across both fuel variants. Confirm against the DVEL8 parts list in the appliance owner's manual or contact Eskabe to verify part fitment for a specific appliance serial number if any uncertainty exists.

What wall thickness range can the DVEL8 vent assembly accommodate?

The Eskabe DVEL8 direct vent assembly is designed to pass through exterior walls up to 10 inches thick. This accommodates most standard residential exterior wall constructions, including 2-inch by 4-inch framed walls with interior and exterior finishes, 2-inch by 6-inch framed walls with insulation and finishes, and many masonry or concrete block wall constructions within that thickness range. For walls thicker than 10 inches, consult the DVEL8 owner's manual and the Eskabe installation guidance for the appropriate extension or modification to accommodate the greater wall depth. The wall opening must be correctly sized for the vent assembly per the DVEL8 installation instructions — the installation and service must be performed by a qualified installer, service agency, or the gas supplier.

What other Eskabe DVEL8 replacement parts are available alongside the 5089?

The Eskabe DVEL8 is a serviceable gas appliance with a range of genuine OEM replacement parts available to maintain it in long-term operation. The companion vent pipe — the inner exhaust pipe — is the Eskabe 5134 Vent Pipe. Additional DVEL8 replacement parts available from Rural Energy include components for the gas valve, pilot assembly, piezoelectric ignitor, orifices, gaskets, and other wear items as listed in the DVEL8 owner's manual parts list. When ordering replacement parts, confirm the specific model variant — DVEL8N for natural gas or DVEL8L for propane — as some internal gas train components differ between fuel types. The DVEL8 owner's manual parts list provides the complete part reference for identifying and ordering all serviceable components.