Eskabe Vent Pipe, DVEL8

5134

Status: In Stock

US$25.99

Description

Description

The Eskabe Vent Pipe, part number 5134, is the inner exhaust pipe replacement part for the Eskabe DVEL8 gravity direct vent wall furnace vent kit. In the DVEL8's coaxial — dual-wall — direct vent assembly, the 5134 Vent Pipe is the center pipe that carries hot combustion gases from the appliance burner outward through the wall to the exterior.

The companion outer pipe — the Eskabe 5089 Vent-Air Intake Pipe — surrounds the 5134 and draws cooler outside combustion air inward through the annular space between the two pipes to supply the burner. Together the 5134 inner exhaust pipe and the 5089 outer air intake pipe form the complete DVEL8 coaxial vent assembly, allowing the appliance to both exhaust flue gases and draw combustion air through a single wall penetration.

The DVEL8 is a non-electric, 8,000 BTU/h gravity direct vent wall furnace available in natural gas (DVEL8N) and propane (DVEL8L) configurations. The vent assembly passes through any exterior wall up to 10 inches thick and requires no special insulation or fireproofing at the wall opening — the coaxial design's incoming combustion air cools the outer pipe surface as it flows inward, keeping the wall penetration at a safe temperature during operation.

The 5134 inner exhaust pipe is the component most directly exposed to the hot combustion gases produced by the burner, and it is the exhaust pipe that channels those gases reliably from the appliance outlet to the exterior termination point at the outer face of the wall.

The 5134 is a genuine Eskabe OEM replacement part — installation and service must be performed by a qualified installer, service agency, or the gas supplier in accordance with local codes.

What's Included: One Eskabe 5134 Vent Pipe replacement part — the inner exhaust pipe of the DVEL8 coaxial direct vent assembly.

Installation Limits: For use with the Eskabe DVEL8 gravity direct vent wall furnace only. The companion outer air intake pipe is the Eskabe 5089 Vent-Air Intake Pipe, sold separately. Wall penetration accommodates walls up to 10 inches thick. Installation and service must be performed by a qualified installer, service agency, or the gas supplier in accordance with local codes. Use only the type of gas indicated on the DVEL8 rating plate.

Compatibility: Genuine Eskabe OEM replacement part for the DVEL8 gravity direct vent wall furnace vent kit — natural gas (DVEL8N) and propane (DVEL8L) models.

Features

Features

  • Genuine Eskabe OEM replacement vent pipe for the DVEL8 gravity direct vent wall furnace — the inner exhaust pipe of the coaxial vent assembly that carries hot combustion gases from the appliance burner outward through the wall to the exterior
  • Works in tandem with the Eskabe 5089 Vent-Air Intake Pipe — the outer pipe surrounds the 5134 and draws combustion air inward while the 5134 exhausts flue gases outward, both flowing through a single wall penetration
  • Compatible with DVEL8 vent installations through exterior walls up to 10 inches thick — no special insulation or fireproofing of the wall opening required
  • The 5134 is the inner pipe most directly exposed to hot combustion gases — genuine OEM construction ensures correct fit and material compatibility with the DVEL8 appliance
  • For use with the Eskabe DVEL8 8,000 BTU/h non-electric gravity direct vent wall furnace — compatible with both natural gas (DVEL8N) and propane (DVEL8L) models
  • Installation and service must be performed by a qualified installer, service agency, or the gas supplier in accordance with all applicable local codes

Specifications

Specifications

Part Number: 5134
Brand: Eskabe
Part Type: Vent Pipe — Inner Coaxial Exhaust Pipe
Compatible Appliance: Eskabe DVEL8 Gravity Direct Vent Wall Furnace
Compatible Models: DVEL8N (Natural Gas) and DVEL8L (Propane)
Appliance Input: 8,000 BTU/h
Vent System Type: Coaxial Direct Vent — Dual-Wall
Pipe Function: Inner Exhaust — Carries Combustion Gases from Appliance to Exterior
Wall Thickness Accommodation: Up to 10 Inches
Companion Part: Eskabe 5089 Vent-Air Intake Pipe — Outer Air Intake Pipe — Sold Separately
Part Status: Genuine Eskabe OEM Replacement Part

 

The Eskabe 5134 is the genuine OEM replacement vent pipe — the inner exhaust pipe of the DVEL8 coaxial direct vent assembly — for the Eskabe DVEL8 8,000 BTU/h non-electric gravity direct vent wall furnace, carrying combustion gases from the appliance to the exterior through walls up to 10 inches thick, with companion outer air intake pipe Eskabe 5089 sold separately.

 

Support

Support

 
Product FAQ

What is the role of the 5134 Vent Pipe in the DVEL8 vent system?

The 5134 Vent Pipe is the inner pipe of the DVEL8 coaxial vent assembly — it is the exhaust pipe that carries hot combustion gases from the DVEL8 burner outward through the wall to the exterior termination. In the coaxial design, the 5134 runs through the center of the assembly, surrounded by the outer 5089 air intake pipe. Flue gases exit the appliance burner, travel through the 5134 toward the exterior, and discharge at the outside face of the wall. Simultaneously, fresh outside combustion air travels inward through the annular space between the 5134 outer surface and the inner surface of the surrounding 5089 pipe, reaching the appliance burner to sustain combustion. The 5134 is the component most directly exposed to heat and combustion gas chemistry, making it a key serviceable component of the vent assembly.

How does the 5134 Vent Pipe differ from the 5089 Vent-Air Intake Pipe?

The 5134 and 5089 are the two pipe components of the DVEL8 coaxial vent assembly, serving opposite functions in opposite directions. The 5134 is the inner pipe — it exhausts hot flue gases from the appliance burner outward through the wall to the exterior. The 5089 is the outer pipe — it surrounds the 5134 and draws cooler combustion air inward from the exterior through the annular space between the pipes to supply the burner. The 5134 is typically more susceptible to corrosion and degradation over time because it is in direct contact with hot, acidic combustion gases throughout every operating cycle, while the 5089 carries only incoming ambient air. When servicing the vent assembly, the specific pipe that has failed must be correctly identified before ordering the replacement part.

What are the signs that the 5134 Vent Pipe may need to be replaced?

Indicators that the 5134 inner exhaust pipe may require replacement include visible corrosion, pitting, holes, or physical damage to the pipe body; rust staining or discoloration on the pipe exterior that extends beyond normal surface oxidation; evidence of flue gas leakage into the wall cavity such as soot staining, unusual odors near the appliance, or discoloration of wall surfaces around the vent penetration; and any physical deformation of the pipe that would prevent it from seating correctly in the vent assembly. Any suspected degradation of the exhaust pipe should be inspected and evaluated by a qualified service technician — the DVEL8 installation manual requires that inspection and service be performed by a qualified installer, service agency, or the gas supplier.

Should the 5134 and 5089 be replaced together or can each be replaced independently?

Each pipe component can be replaced independently — the 5134 Vent Pipe and the 5089 Vent-Air Intake Pipe are separate OEM replacement parts available individually from Rural Energy. If only one pipe has visibly failed or is damaged, the specific failed component can be replaced without necessarily replacing the other. However, when either pipe is removed for replacement, the service technician has the opportunity to inspect the condition of the remaining pipe at the same time — if both pipes show significant age-related wear or corrosion, replacing both simultaneously during a single service visit is more cost-effective than making a second service visit in the near future for the other pipe. The qualified service technician performing the work should evaluate the condition of both pipes and recommend accordingly.

Is the 5134 compatible with both natural gas and propane DVEL8 models?

Yes. The 5134 Vent Pipe is a vent assembly component that is mechanically the same for both the natural gas DVEL8N and the propane DVEL8L versions of the DVEL8. The vent pipe's function — exhausting combustion gases from the burner outward through the wall — is the same regardless of whether the fuel is natural gas or propane, and the vent pipe is not a fuel-specific component. The differences between the DVEL8N and DVEL8L models are in the gas valve, injector orifice, and pressure regulator specifications — not in the vent assembly. Confirm against the DVEL8 parts list in the appliance owner's manual to verify part fitment for a specific appliance serial number if any uncertainty exists.

What other Eskabe DVEL8 replacement parts are available alongside the 5134?

Rural Energy carries a range of genuine Eskabe OEM replacement parts for the DVEL8 and the broader Eskabe DVEL heater range. The companion outer vent pipe is the Eskabe 5089 Vent-Air Intake Pipe. Additional DVEL8 replacement parts include gas valve components, pilot assemblies, piezoelectric ignitors, injector orifices for both natural gas and propane, gaskets, ignitor wires, and other serviceable components as listed in the DVEL8 owner's manual parts list. The full DVEL8 parts list is contained in the owner's manual covering the DVEL8, DVEL12, and DVEL20 models. Confirming part numbers against the parts list diagram for the specific appliance model and serial number before ordering is recommended to ensure the correct replacement part is selected.

To top