Duravent Stove Pipe DuraTech Firestop Radiation Shield, 5"

5DT-FRS

Status: In Stock

US$69.33

Description

Description

The DuraVent DuraTech Firestop Radiation Shield, part number 5DT-FRS, is the required floor and ceiling penetration firestop component for the DuraTech 5-inch Class A chimney system when the chimney passes through a floor or ceiling without the use of a support box.

The Firestop Radiation Shield is installed on the underside of the ceiling at the penetration point, centering the chimney pipe within the framing opening and assuring the proper clearance to combustibles required by the DuraTech system at all floor and ceiling penetrations. Its adjustable design accommodates wide framing configurations at the penetration opening. The 5DT-FRS is not required when the chimney passes through the roof — it is specifically a floor and ceiling penetration component for intermediate floor and ceiling levels within the building structure.

A floor or ceiling penetration in a DuraTech chimney installation is either managed by a support box — which both supports the chimney and provides the required fire separation at the penetration — or, where a support box is not used, by the Firestop Radiation Shield. The 5DT-FRS provides the code-required fire separation and clearance assurance at the penetration point without the structural chimney support function of a support box.

In a multi-storey installation where the chimney passes through an intermediate floor before reaching a support box at a higher level, the 5DT-FRS manages each intermediate floor penetration. Where the DuraTech chimney run passes through an attic, the 5DT-AIS Attic Insulation Shield is additionally required — the Attic Insulation Shield fits directly over the Firestop Radiation Shield in the attic space and prevents insulation and debris from accumulating against the chimney pipe.

What's Included: One DuraVent DuraTech 5DT-FRS firestop radiation shield for the DuraTech 5-inch chimney system, for installation at floor and ceiling penetrations without a support box.

Installation Limits: Required at all floor and ceiling penetrations where a DuraTech support box is not used. Fits on the underside of the ceiling at the penetration. Not required at roof penetrations. When the chimney passes through an attic, the 5DT-AIS Attic Insulation Shield must additionally be installed over the 5DT-FRS. All installation must comply with local building codes and the DuraTech installation instructions. DuraVent limited lifetime warranty applies only when installed by a qualified professional installer.

Compatibility: Compatible with the DuraVent DuraTech 5-inch Class A double-wall all-fuel chimney system.

Features

Features

  • DuraVent DuraTech 5-inch firestop radiation shield — required at floor and ceiling penetrations where the chimney passes through without the use of a support box
  • Installed on the underside of the ceiling at the penetration point, centering the pipe within the framing opening and assuring the proper clearance to combustibles required by the DuraTech system
  • Adjustable design accommodates wide framing configurations at the penetration opening
  • Not required at roof penetrations — specifically a floor and ceiling penetration component for intermediate levels within the building structure
  • When the chimney passes through an attic, the 5DT-AIS Attic Insulation Shield must additionally be installed over the 5DT-FRS to prevent insulation and debris from accumulating against the chimney pipe
  •  DuraVent limited lifetime warranty applies when installed by a qualified professional installer

Specifications

Specifications

Part Number: 5DT-FRS
Brand: DuraVent
System: DuraTech Class A Double-Wall All-Fuel Chimney
Inner Diameter: 5 inches
Part Type: Firestop Radiation Shield
Installation Location: Floor and Ceiling Penetrations — Underside of Ceiling
Required When: Chimney Passes Through Floor or Ceiling Without a Support Box
Not Required At: Roof Penetrations
Attic Installations: 5DT-AIS Attic Insulation Shield Must Be Installed Over 5DT-FRS
Listings: UL 103 HT and Canadian S610

 

The DuraVent 5DT-FRS is the DuraTech 5-inch firestop radiation shield for floor and ceiling penetrations where a support box is not used — installed on the underside of the ceiling to center the pipe and assure proper clearance to combustibles, not required at roof penetrations, and paired with the 5DT-AIS Attic Insulation Shield in attic installations.

 

Support

Support

 
Product FAQ

What is the function of the 5DT-FRS firestop radiation shield?

The 5DT-FRS firestop radiation shield performs two key functions at floor and ceiling penetrations. It centers the chimney pipe within the framing opening to maintain the required 2-inch clearance to combustibles uniformly around the pipe at the penetration point, preventing the pipe from shifting toward the framing during or after installation. It also provides the code-required fire separation at the penetration by blocking the direct pathway between the chimney pipe and the combustible framing materials at the floor or ceiling level, reducing the risk of heat transfer or fire propagation through the penetration opening. The adjustable design of the shield accommodates varying framing dimensions at the penetration and the shield plate fits on the underside of the ceiling to cover the framing opening with a finished appearance.

When is the 5DT-FRS required versus when a support box is used?

The 5DT-FRS is required at floor and ceiling penetrations where a DuraTech support box is not installed. A DuraTech support box — such as a ceiling support box or floor support box — performs both the structural support function and the fire separation function at a penetration point where the chimney is supported, and in those locations the support box itself provides the code-required penetration protection so the 5DT-FRS is not additionally needed. Where the chimney passes through an intermediate floor or ceiling that is not a support point — for example, a floor level between the appliance and the first ceiling support location — the 5DT-FRS provides the required fire separation at that penetration without providing structural support. Both components serve related but distinct purposes within the DuraTech installation.

Why is the 5DT-FRS not required at roof penetrations?

At roof penetrations, the fire separation and weather protection functions are provided by the roof flashing and storm collar components rather than by a firestop radiation shield. The roof flashing is installed at the roof deck level to provide a weather-tight seal around the chimney pipe as it exits through the roof, and it also provides the structural separation between the pipe and the combustible roof deck framing at that location. The 5DT-FRS is designed for interior floor and ceiling penetrations where the chimney transitions between occupied building levels — at those interior locations the fire separation requirement applies but a weather seal is not needed. The roof penetration requires a different set of components suited to the exterior environment.

What is the 5DT-AIS Attic Insulation Shield and why is it required in attic installations?

The 5DT-AIS Attic Insulation Shield is a two-part component — consisting of a collar and a base with a mesh sleeve at the top — that fits over the 5DT-FRS firestop radiation shield in the attic space. It is required whenever the DuraTech chimney run passes through an attic because loose-fill attic insulation and debris can accumulate against the chimney pipe in the attic if left uncontained, creating both a fire risk from combustible material in contact with the hot chimney and a practical maintenance problem. The Attic Insulation Shield creates a protected zone around the chimney pipe in the attic space that keeps insulation and debris at a safe distance from the pipe, while the mesh sleeve at the top prevents material from falling down into the shield from above.

How many 5DT-FRS units are needed in a typical DuraTech chimney installation?

One 5DT-FRS is required for each floor or ceiling penetration where a support box is not used. In a single-storey installation where the chimney passes through one ceiling and then one roof, the ceiling penetration may be managed by a support box or by a 5DT-FRS — one unit would be required if the 5DT-FRS approach is used rather than a support box at that level. In a multi-storey installation, each intermediate floor penetration that does not have a support box requires one 5DT-FRS. The number required therefore depends on the number of floor and ceiling levels the chimney passes through and whether each of those penetrations uses a support box or the firestop radiation shield approach. The DuraTech installation instructions specify which penetrations require each component type.

What other DuraTech 5-inch components work alongside the 5DT-FRS?

The 5DT-FRS works alongside the straight pipe sections — such as the 5DT-09SS and 5DT-12SS — that pass through the penetration it protects. The 5DT-AIS Attic Insulation Shield fits over the 5DT-FRS wherever the chimney runs through an attic. The DuraTech ceiling support box or floor support box is the alternative to the 5DT-FRS at penetrations where structural chimney support is also required at that level. The 5DT-E15KSS and 5DT-E30KSS elbow kits may be used in the chimney run above or below the firestop location to route around obstructions. The roof flashing, storm collar, and chimney cap complete the system above the final ceiling or floor penetration at the roof exit level.