Osburn Fresh Air Intake Register W/ Airtight Damper 5"

AC01349

Status: In Stock

US$260.00

Description

Description

The Osburn Fresh Air Intake Register with Airtight Damper, part number AC01349, is a 5-inch diameter fresh air intake register with airtight damper for use with Osburn wood stoves, inserts, and fireplaces certified with a 5-inch fresh air intake kit. The register is the wall-mounted termination fitting of the fresh air intake system that is visible from inside the installation space, providing a controlled opening point where outside combustion air enters the fresh air intake pipe that supplies the heating appliance.

The airtight damper within the register can be closed completely when the heating appliance is not in operation, preventing cold outside air from flowing back through the fresh air intake pipe into the installation space and reducing unwanted heat loss through the intake system during non-operation periods.

Fresh air intake systems supply dedicated outside combustion air directly to the heating appliance, drawing air from outside the building structure rather than from the room air within the installation space. This is required or recommended in tightly constructed homes where the building envelope does not provide sufficient natural air infiltration to supply adequate combustion air to the heating appliance, and is required in some jurisdictions by local building code for certain wood stove and insert installations.

The AC01349 register is constructed of steel for durability and includes a built-in positioning shim that allows precise installation adjustment based on the wall thickness at the installation point, ensuring the register face sits flush and correctly positioned at the wall surface regardless of the specific wall construction depth. The simple lever or plate damper mechanism within the register requires no tools to operate and allows the damper to be opened before lighting the appliance and closed after it has been fully extinguished and cooled.

What's Included: One Osburn AC01349 5-inch diameter fresh air intake register with airtight damper.

Installation Limits: The AC01349 is sized for use with 5-inch fresh air intake kits only. All fresh air intake installation must comply with local building codes and all applicable standards governing combustion air supply for wood and pellet heating appliances. All installation must follow the Osburn AC01349 installation instructions and the owner's manual for the specific heating appliance being served.

Compatibility: Compatible with Osburn wood stoves, inserts, and fireplaces certified with a 5-inch fresh air intake kit.

Features

Features

  • 5-inch diameter fresh air intake register with airtight damper for Osburn wood stoves, inserts, and fireplaces certified with a 5-inch fresh air intake kit
  • Airtight damper closes completely when the heating appliance is not in operation, preventing cold outside air from flowing back through the intake pipe and reducing heat loss through the intake system
  • Steel construction provides long-term durability at the fresh air intake register position at the wall surface
  • Built-in positioning shim allows precise installation adjustment based on wall thickness, ensuring the register face sits flush and correctly positioned at the wall surface regardless of wall construction depth
  • Simple damper mechanism requires no tools to operate — open before lighting the appliance and close after the appliance is fully extinguished and cooled
  • All installation must comply with local building codes governing combustion air supply and follow the AC01349 installation instructions and the owner's manual for the specific appliance being served

Specifications

Specifications

Part Number: AC01349
Brand: Osburn
Manufacturer: Stove Builder International (SBI)
Part Type: Fresh Air Intake Register with Airtight Damper
Diameter: 5 inches
Damper Type: Airtight
Construction: Steel
Wall Thickness Adjustment: Built-In Positioning Shim
Compatibility: Osburn Wood Stoves, Inserts, and Fireplaces Certified with 5-Inch Fresh Air Intake Kit

 

The Osburn AC01349 Fresh Air Intake Register with Airtight Damper is a 5-inch diameter steel fresh air intake register with airtight damper and built-in positioning shim for Osburn wood stoves, inserts, and fireplaces certified with a 5-inch fresh air intake system, providing a controllable wall termination point for the combustion air supply with an airtight closure to prevent cold air backflow when the appliance is not in operation.

 

Support

Support

 
Product FAQ

What is the purpose of a fresh air intake system on a wood stove or insert installation?

A fresh air intake system supplies dedicated outside combustion air directly to the heating appliance through a pipe running from the exterior of the building to a connection point at or near the stove or insert, drawing air from outside rather than from the room air within the installation space. This is required or recommended in tightly constructed homes where natural air infiltration through the building envelope is insufficient to supply adequate combustion air to the heating appliance. Some local building codes require a fresh air intake for wood stove and insert installations in new construction or energy-efficient buildings. The fresh air intake register AC01349 is the wall-mounted termination fitting where outside air enters the intake pipe at the interior wall surface.

Why is the airtight damper on the AC01349 register important?

The airtight damper allows the fresh air intake opening to be completely closed when the heating appliance is not in operation. Without a closable damper, the fresh air intake pipe would remain permanently open to outside air, allowing cold outside air to flow continuously into the installation space through the intake pipe and creating a persistent source of heat loss and drafts. Closing the airtight damper when the appliance is off eliminates this air pathway, retaining the building's thermal envelope and preventing the fresh air intake system from becoming a cold air infiltration point during non-heating periods.

What is the built-in positioning shim on the AC01349 and why is it useful?

The built-in positioning shim on the AC01349 allows the register to be precisely adjusted for the specific wall thickness at the installation point, ensuring the register face sits flush and correctly positioned at the wall surface regardless of the depth of the wall construction. Different installation locations may have different wall thicknesses depending on insulation type, framing depth, and wall finish materials. The positioning shim eliminates the need to source separate spacers or make custom depth adjustments, simplifying the installation process and ensuring a clean flush-mounted appearance at the wall surface.

What is the correct operating procedure for the AC01349 damper during stove use?

The damper on the AC01349 should be opened before lighting the heating appliance to allow outside combustion air to flow through the fresh air intake pipe to the appliance during operation. The damper should remain open throughout the entire operating period while the appliance is burning. Once the fire is fully extinguished and the appliance has cooled completely, the damper may be closed to prevent cold outside air from flowing back through the intake pipe into the installation space during the non-operation period. The damper must always be in the open position during any period when the appliance contains an active fire.

Is the AC01349 compatible with 4-inch fresh air intake kits as well as 5-inch kits?

No. The AC01349 is a 5-inch diameter register sized for use specifically with 5-inch fresh air intake kits. A separate 4-inch diameter register is available as AC01348 for appliances certified with a 4-inch fresh air intake kit. The register diameter must match the diameter of the fresh air intake pipe and kit specified for the specific heating appliance being served — confirming the correct fresh air intake kit diameter against the owner's manual or installation instructions for the appliance before ordering the register is essential to ensure the correct register size is selected.

What installation requirements apply to the AC01349 fresh air intake register?

All fresh air intake installation must comply with local building codes and all applicable standards governing combustion air supply for wood and pellet heating appliances in the jurisdiction where the installation is located. The AC01349 installation must follow the Osburn AC01349 installation instructions and the fresh air intake installation requirements specified in the owner's manual for the specific heating appliance being served. Installation by a qualified installer is recommended to ensure the fresh air intake system is correctly sized, routed, and connected to the appliance in compliance with all applicable requirements.

To top