Duravent Stove Pipe DuraTech Roof Flashing Adj 0/12-6/12, 5"

5DT-F6

Status: In Stock

US$141.99

Description

Description

The DuraVent DuraTech Roof Flashing, part number 5DT-F6, is the adjustable galvalume roof flashing for the DuraTech 5-inch Class A double-wall all-fuel chimney system, covering roof pitches from flat — 0/12 — to 6/12. The roof flashing is the component that weatherproofs the penetration of the DuraTech chimney pipe through the roof deck, providing a weather-tight seal at the point where the chimney pipe exits the building through the roof surface.

Without a correctly fitted roof flashing at this penetration, the gap between the chimney pipe and the roof deck would allow rain, snow, and wind-driven moisture to enter the building through the roof penetration, causing water damage to the building structure and interior. The 5DT-F6 is selected based on the pitch of the roof at the chimney penetration location — it accommodates roof pitches from flat through 6/12, where 6/12 indicates a vertical rise of 6 inches over a horizontal distance of 12 inches.

The 5DT-F6 is constructed of galvalume — a steel alloy coated with an aluminum-zinc alloy — which provides corrosion resistance appropriate for an exterior roof-mounted component exposed to the outdoor weather environment throughout the service life of the chimney installation. The flashing is adjustable within its pitch range, allowing it to conform to the specific roof pitch at the installation site.

A storm collar is required in addition to the roof flashing — the storm collar installs on the chimney pipe above the flashing cone and is sealed with high-temperature caulk or mastic to prevent water from tracking down the chimney pipe exterior and entering beneath the top edge of the flashing.

The storm collar is sold separately. For installations on roofs with pitches steeper than 6/12, separate DuraTech roof flashing part numbers are available covering 7/12 to 12/12, 13/12 to 18/12, and steeper pitch ranges.

What's Included: One DuraVent 5DT-F6 DuraTech 5-inch adjustable galvalume roof flashing for 0/12 to 6/12 roof pitch. Storm collar sold separately — order 5DT-SC.

Installation Limits: For roof pitches from flat (0/12) to 6/12 only — select a different flashing part number for steeper pitches. Storm collar 5DT-SC required and sold separately. For use with the DuraTech 5-inch Class A chimney system only. All installation must comply with local building codes and the DuraTech installation instructions. DuraVent limited lifetime warranty applies only when installed by a qualified professional installer.

Compatibility: Compatible with the DuraVent DuraTech 5-inch Class A double-wall all-fuel chimney system. For use with wood stoves, fireplaces, furnaces, boilers, ranges, water heaters, and other appliances fueled by wood, oil, coal, or gas that are tested and listed for use with a 2,100°F HT chimney system.

Features

Features

  • DuraVent DuraTech 5-inch adjustable galvalume roof flashing for 0/12 to 6/12 roof pitch — weatherproofs the penetration of the DuraTech chimney pipe through the roof deck
  • Covers flat roofs through 6/12 pitch — a 6/12 pitch has a vertical rise of 6 inches over a horizontal distance of 12 inches — select a different part number for pitches steeper than 6/12
  • Adjustable design conforms to the specific roof pitch within the 0/12 to 6/12 range at the chimney penetration location
  • Galvalume construction — aluminum-zinc alloy coated steel — provides corrosion resistance for an exterior roof-mounted component exposed to outdoor weather throughout the chimney service life
  • Storm collar 5DT-SC required and sold separately — installs on the chimney pipe above the flashing and seals the top edge to prevent water infiltration beneath the flashing
  • DuraVent limited lifetime warranty applies when installed by a qualified professional installer — all installation must comply with local building codes and the DuraTech installation instructions

Specifications

Specifications

Part Number: 5DT-F6
Brand: DuraVent
System: DuraTech Class A Double-Wall All-Fuel Chimney
Inner Diameter: 5 inches
Part Type: Roof Flashing — Adjustable
Roof Pitch Range: 0/12 (Flat) to 6/12
Construction: Galvalume — Aluminum-Zinc Alloy Coated Steel
Storm Collar: Required — 5DT-SC Sold Separately
Pitch Selection: Select Based on Roof Pitch at Chimney Penetration — Steeper Pitch Flashings Available Separately

 

The DuraVent 5DT-F6 is an adjustable galvalume roof flashing for the DuraTech 5-inch Class A chimney system, weatherproofing chimney pipe penetrations through roofs with pitches from flat through 6/12 — storm collar 5DT-SC required and sold separately, with separate flashing part numbers available for pitches steeper than 6/12.

 

Support

Support

 
Product FAQ

How do I determine whether the 5DT-F6 is the correct roof flashing for my installation?

The correct DuraTech roof flashing is selected based on the pitch of the roof at the chimney penetration location. Roof pitch is expressed as a ratio of vertical rise over horizontal run — for example, a 6/12 pitch rises 6 inches vertically for every 12 inches of horizontal distance. The 5DT-F6 covers pitches from flat — 0/12 — through 6/12. To measure the roof pitch, use a level or pitch gauge against the roof surface at the chimney penetration location and read the rise-to-run ratio. If the roof pitch at the penetration is 6/12 or shallower — including a flat roof — the 5DT-F6 is the correct flashing. If the pitch is steeper than 6/12, a different DuraTech roof flashing part number covering the steeper pitch range must be selected instead. Measuring the pitch at the actual penetration location is important because roof pitch can vary in complex roof geometries.

Why is a storm collar required in addition to the roof flashing, and which storm collar is used with the 5DT-F6?

The roof flashing seals the opening in the roof deck around the chimney pipe from below, but the top edge of the flashing cone fits around the pipe with a gap that allows the pipe to pass through without being rigidly connected to the flashing — this gap is necessary to accommodate thermal expansion and movement of the chimney pipe during operation. Without a storm collar sealed above this gap, water can track down the exterior surface of the chimney pipe and enter beneath the top edge of the flashing cone into the building. The storm collar installs on the chimney pipe above the flashing and is sealed with high-temperature sealant or caulk at its top edge to prevent water from entering between the pipe and the collar — forming a watertight barrier that directs water away from the flashing top gap. The 5DT-SC storm collar for 5-inch and 6-inch DuraTech pipe is the appropriate storm collar for use with the 5DT-F6.

What DuraTech roof flashings are available for pitches steeper than 6/12?

DuraVent offers additional DuraTech 5-inch roof flashing part numbers for steeper pitch ranges beyond the 5DT-F6's 0/12 to 6/12 coverage. A separate flashing covers the 7/12 to 12/12 pitch range, and another covers 13/12 to 18/12. For very steep pitches beyond 18/12, additional flashing options are available. Each flashing is designed to accommodate the specific geometry of the roof surface at the given pitch range, ensuring a properly angled flashing base that sits flush against the roof surface and provides a weather-tight seal. Selecting the wrong pitch range flashing — for example, using a 0/12 to 6/12 flashing on a 9/12 pitch roof — would result in a poor fit that cannot be sealed correctly, creating a high risk of water infiltration at the roof penetration.

Why is galvalume used for the 5DT-F6 rather than stainless steel?

Galvalume — steel coated with an aluminum-zinc alloy — is the standard construction material for DuraTech roof flashings because it provides adequate weather resistance and corrosion protection for an exterior component in a typical residential roofing environment, while being more formable and cost-effective than stainless steel for the large flat base sections required in a flashing. Galvalume's aluminum-zinc coating provides superior corrosion resistance compared to galvanized steel in most residential roofing environments, and its formability allows the flashing base to be shaped to conform to the roof pitch and overlap the roofing material correctly. Stainless steel outer wall options on DuraTech pipe sections are recommended for outdoor weather-exposed pipe sections, but the galvalume flashing is the standard DuraVent specification for the roof flashing component itself.

Does the 5DT-F6 require any modifications for metal roof installations?

The 5DT-F6 is a standard galvalume roof flashing designed for conventional shingle or tile roofing applications. Metal roofing systems — standing seam, corrugated, or other metal roofing profiles — often require specialized flashing configurations because the raised seams, corrugated profile, or expansion and contraction characteristics of metal roofing create different sealing challenges than flat shingle surfaces. For metal roof installations, consult the roofing manufacturer's recommendations for chimney flashing details and confirm whether the standard 5DT-F6 flashing is compatible with the specific metal roofing system or whether a specialized flashing configuration is required. The DuraTech installation instructions also provide guidance on flashing installation for different roofing materials.

What other DuraTech 5-inch components complete the exterior roof termination above the 5DT-F6?

Above the 5DT-F6 roof flashing, the DuraTech 5-inch exterior roof termination requires the 5DT-SC storm collar installed on the chimney pipe immediately above the flashing cone and sealed with high-temperature sealant, followed by the required chimney pipe sections extending at least 3 feet above the roof penetration point and at least 2 feet above any portion of the building within 10 feet of the chimney, and a chimney cap at the top to prevent rain, snow, debris, and animals from entering the flue while allowing flue gases to exit. If the chimney extends more than approximately 4 to 5 feet above the roof penetration, the 5DT-XRS extended roof bracket is required to brace the exposed chimney against wind loads. The locking band 5DT-LB may optionally be applied at joints in the exposed above-roof section for additional security.