Roth double-wall heating oil tanks store your fuel in a seamless plastic inner tank surrounded by a galvanized steel outer tank. Four sizes cover most homes and cabins: 110, 165, 275 and 400 gallons. The 275-gallon DWT 1000L is the standard residential size. For help choosing, read our guide to heating oil tank sizes.

How a Roth Tank Is Built

  • Seamless, blow-molded high-density polyethylene inner tank that cannot rust.
  • Galvanized 19-gauge steel outer tank, roll seamed with no welds, built to hold at least 110% of the inner tank if it ever leaks.
  • All connections on top, so there are no fittings below the oil line.
  • Highly visible optical leak alarm.
  • Pressure tested at the factory, so no field pressure test is required.
  • Corrosion-resistant steel filling system with an external 2″ thread, so tanks installed in groups fill to an even level.

Approved Fuels

Roth's 2023 installation manual approves the DWT for #2 fuel oil, diesel fuel and bio-fuels up to B100. Rural Energy has confirmed that Roth tanks are also rated for K-1 kerosene storage. The tank and your heater are separate approvals, so confirm that your appliance accepts the fuel too. Our guide to kerosene, heating oil and diesel shows which fuel goes in which heater.

Listings and Codes

The Roth DWT is listed in the United States and Canada (cULus) under UL 2258, the standard for aboveground nonmetallic fuel oil tanks, and is approved under NFPA 31 and CSA B139. UL 80, often quoted for oil tanks, is the steel-tank standard and does not apply to this design. Local fuel storage codes and permit rules apply to every installation.

Indoor and Outdoor Installation

Roth tanks are designed for indoor installation, including basements. Indoors, keep the tank's plastic parts out of direct sunlight. Outdoors, every tank needs its matching Roth cover. Check the minimum ceiling height for your size in the Specifications tab before you order.

Ordering From Rural Energy

We help you choose the right size by phone or email, and we ship Roth tanks outside Alaska and the Pacific Northwest. Rural Energy does not install tanks: the 30-year warranty requires installation by a Roth Certified Installer, so line one up before your tank arrives. Contact us or call (907) 278-7441.

Related reading: how to fix and prevent oil tank leaks and how long stored heating fuel keeps.

Features

Features

  • Up to 50% lighter than conventional steel tanks.
  • Wide handles on each end facilitate transport and handling.
  • Removable base facilitates access to tight spaces and offers greater stability.
  • Compact and economical design. (8 sq. ft. for 1000L)
  • No fittings below the oil line.
  • Unique expansion system ensures increased storage capacity and faster, easier fill-ups.
  • Completely sealed, every one of our tanks is pressure tested and meets exacting quality control standards.
  • Premier Industry Warranty of 30 years with 10 years insurance, $2 million clean-up policy*

*Roth double-wall oil storage tanks come with a 30-year warranty when installed by a Roth Certified Installer. 

Specifications

Specifications

Model DWT 400L DWT 620L DWT 1000L DWT 1500L
Nom. Capacity U.S. Gal (liters) 110 (400) 165 (620) 275 (1000) 400 (1500)
Length: inches (cm) 29 (74) 29 (74) 43 (110) 64 (163)
Width: inches (cm) 28 (72) 28 (72) 28 (72) 30 (77)
Height: inches (cm) 44 (112) 61 (155) 61 (155) 68 (173)
Min. Height: Inches (cm) 49 (125) 66 (168) 66 (168) 76 (193)
Tank Weight: lbs. (kg) 106 (48) 132 (60) 167 (76) 333 (151)
Shipping Weight: lbs. (kg) 115 (52) 143 (65) 185 (84) 358 (162)

 

Support

Support

 
People Also Ask:

Q. What Do the DWT 400L, 620L, 1000L and 1500L Model Names Mean?

A. The number is the tank's nominal capacity in liters. The DWT 400L holds 110 U.S. gallons, the 620L holds 165, the 1000L holds 275 and the 1500L holds 400. Installation kits and covers are sold by the same model names, so it helps to know which one you have. The 400L and 620L share the same 29 by 28 inch footprint and differ only in height, 44 versus 61 inches. The 1000L measures 43 by 28 inches and stands 61 inches tall, and the 1500L measures 64 by 30 inches and stands 68 inches tall. Each size also has its own page: the 110-gallon DWT 400L, the 165-gallon DWT 620L, the 275-gallon DWT 1000L and the 400-gallon DWT 1500L.

Q. Which Roth Installation Kit Fits My Tank?

A. Roth installation kits are sold separately and are matched to the tank model. The 110-gallon DWT 400L uses the 400L kit in 3/8 inch. The 165-gallon and 275-gallon tanks share one kit design, offered in 3/8 inch and 1/2 inch versions. The 400-gallon DWT 1500L kit also comes in 3/8 inch and 1/2 inch versions. Your installer will know which connection size your fuel line and heater need, so confirm it with them before you order. If you are unsure, send us your tank model and your heater model and we will help you pick the matching kit, so the tank and its fittings arrive together and the installation can be completed in one visit.

Q. Which Roth Cover Do I Need for an Outdoor Tank?

A. Roth requires its matching cover whenever the tank is installed outdoors, and the cover is sold separately by model. The 110-gallon DWT 400L and the 165-gallon DWT 620L share the same footprint, so they use one cover for the 400L and 620L. The 275-gallon DWT 1000L uses the cover for the 1000L, and the 400-gallon DWT 1500L uses the cover for the 1500L. Order the cover with the tank so the installation is complete on day one rather than waiting on a second delivery. Indoor tanks do not need a cover. Outdoor installations must also meet your local fuel storage code, which can set its own rules for placement, distance from the building and protection from damage.

Q. Do I Need to Order a Vent Alarm With My Roth Tank?

A. Yes. Roth requires a Roth vent alarm or an equivalent UL-listed whistle vent on every installation to keep the warranty valid. The alarm sits in the vent line and whistles while the tank is filling, then stops as the oil nears the fill level, which tells the delivery driver to stop pumping. That is what protects the tank from overfill. If you are replacing an old tank that already has a whistle vent, ask your installer whether it is UL listed and in good working order before reusing it, since the warranty depends on it. Our heating oil tank guide covers the vent alarm alongside the other steps to plan before a tank replacement.

Q. Can I Connect Two Roth Tanks Together?

A. Yes. Roth designed its filling system for group installations: the corrosion-resistant steel fill connection has an external 2 inch thread, so tanks installed together fill to an even level. Linking tanks is one way to add storage where a single larger tank will not fit, for example two 275-gallon tanks in a space too short for the 400-gallon tank's 64 inch length. The piping layout must follow Roth's instructions and your local fuel storage code, and each tank still needs a Roth Certified Installer to keep its warranty. Plan the layout with your installer before you order, so you buy the right number of tanks, kits and fittings. The Roth installation manual is a useful reference for that conversation.

Q. What Should My Installer Know Before Fitting a Roth Tank?

A. Share Roth's requirements with your installer before the job is scheduled. Fill and vent piping must be black iron or steel. Copper is not permitted, so copper lines left from an old tank have to be replaced, which adds materials and labor to the project. Installation by anyone other than a Roth Certified Installer voids the 30-year warranty, so confirm the certification when you book. The installation must also meet NFPA 31 and your local fuel storage code, and some areas require a permit for a tank replacement. Rural Energy does not install tanks, but we can help you find a certified installer. The full set of requirements is in the Roth installation manual, which is worth sending to your installer in advance.

Q. Will a Roth Tank Fit Where My Old Steel Tank Was?

A. Measure the space, the doorways along the route and the ceiling height before you order. The 110-gallon and 165-gallon tanks need a 29 by 28 inch footprint, the 275-gallon tank 43 by 28 inches and the 400-gallon tank 64 by 30 inches. Height matters as much as footprint. Roth lists a minimum height of 49 inches for the 110-gallon tank, 66 inches for the 165-gallon and 275-gallon tanks and 76 inches for the 400-gallon tank. Roth tanks are up to 50 percent lighter than conventional steel tanks, and the removable base and wide end handles make tight access easier. If one large tank will not fit, two smaller tanks can be linked to reach the same storage.

Q. Does Rural Energy Ship Roth Tanks Outside Alaska?

A. Yes. Rural Energy ships Roth tanks outside Alaska and the Pacific Northwest. Plan for the size and weight of the delivery. The shipping weights are 115 pounds for the 110-gallon DWT 400L, 143 pounds for the 165-gallon DWT 620L, 185 pounds for the 275-gallon DWT 1000L and 358 pounds for the 400-gallon DWT 1500L. Make sure someone can receive the delivery and that you have a way to move the tank into position, especially for a basement installation. For shipping details to your address, contact us with your ZIP code and the model you need. We can also confirm the matching installation kit and cover so everything ships in one order.

Q. What Should I Do If the Leak Alarm Shows a Problem?

A. Roth tanks carry a highly visible optical leak alarm. Check it whenever the tank is filled and during routine inspections. If it ever shows a problem, stop refilling the tank and call a qualified installer to inspect it. The galvanized steel outer tank is built to hold at least 110 percent of the inner tank's capacity, which is the purpose of a double-wall design: fuel that escapes the inner tank is contained instead of reaching the floor or the ground. Leaks can also start at the fuel line, filter or fittings rather than the tank itself, so have those checked at the same visit. Our article on how to fix and prevent oil tank leaks explains the warning signs to watch for.

Q. How Can Rural Energy Help Me Choose the Right Roth Tank?

A. Call or email us and we will help you match the tank to your home. A few details make the conversation quick: your current tank size, how often you take fuel deliveries in winter, where the new tank will go and the measurements of that space, whether it will sit indoors or outdoors, and which fuel and heater you use. With that information we can recommend a size, the matching installation kit and cover, and confirm shipping to your address. Rural Energy has supplied heating equipment from Anchorage since 1987 and works with customers across Alaska, the Pacific Northwest and beyond. Reach us through our contact page or call (907) 278-7441, Monday to Friday, 8:00 AM to 5:00 PM.

 